Search results for "medical applications"
showing 10 items of 18 documents
High Gradient Performance of an S-Band Backward Traveling Wave Accelerating Structure for Medical Hadron Therapy Accelerators
2018
The high-gradient performance of an accelerating structure prototype for a medical proton linac is presented. The structure was designed and built using technology developed by the CLIC collaboration and the target application is the TULIP (Turning Linac for Proton therapy) proposal developed by the TERA foundation. The special feature of this design is to produce gradient of more than 50 MV /m in low-β accelerating structures (v/c=0.38). The structure was tested in an S-band test stand at CERN. During the tests, the structure reached over above 60 MV/m at 1.2 μs pulse length and breakdown rate of about 5x10⁻⁶ bpp. The results presented include ultimate performance, long term behaviour and …
Histone Deacetylase Inhibitors from Marine Invertebrates
2020
Simple Summary Histone deacetylases (HDACs) are enzymes that control gene expression and are involved in the onset of serious human pathologies, including cancer; hence, their inhibitors (HDACis) have received increased attention in recent years. It is known that marine invertebrates produce significant amounts of molecules showing active pharmacological properties and an extensive spectrum of biomedical applications. This review is focused on the description of the molecular, biochemical, and, where available, physiological aspects of marine invertebrate-derived compounds that possess HDACi properties, taking into consideration their possible utilization as treatment agents against differe…
PREPARATION OF MACROMOLECULAR MATERIALS FOR BIOMEDICAL APPLICATIONS
2012
Improving color correction across camera and illumination changes by contextual sample selection
2012
International audience; In many tasks of machine vision applications, it is important that recorded colors remain constant, in the real world scene, even under changes of the illuminants and the cameras. Contrary to the human vision system, a machine vision system exhibits inadequate adaptability to the variation of lighting conditions. Automatic white bal- ance control available in commercial cameras is not sufficient to pro- vide reproducible color classification. We address this problem of color constancy on a large image database acquired with varying digi- tal cameras and lighting conditions. A device-independent color repre- sentation may be obtained by applying a chromatic adaptation…
Functionalization of Graphene with Molecules and/or Nanoparticles for Advanced Applications
2019
Graphene is considered the material of the third millennium, due to its extraordinary electronic and mechanical properties, and due to the possibility to modulate its conductivity, flexibility, elasticity, transparency, and biocompatibility by bottom-up approach. The possibility to gather the proper- ties of graphene and graphene oxide with those of functional moieties or nanoparticles is herein reviewed. The synthetic approaches proposed, either covalent or noncovalent, are aimed to tune appropriately graphene’s properties for the realization of materials for advanced uses, such as bio- medical applications, sensors, catalysis, and energy devices. In particular, methods based on covalent l…
Hyaluronan-Based Graft Copolymers Bearing Aggregation-Induced Emission Flurogens
2017
In order to develop a technology platform based on two natural compounds from biorenewable resources, a short series of hyaluronan (HA) copolymers grafted with propargylated ferulic acid (HA-FA-Pg) were designed and synthesized to show different grafting degree values and their optical properties were characterized in comparison with reference compounds containing the same ferulate fluorophore. Interestingly, these studies revealed that the ferulate fluorophore was quite sensitive to the restriction of intramolecular motion and its introduction into the rigid HA backbone, as in HA-FA-Pg graft copolymers, led to higher photoluminescence quantum yield values than those obtained with the isola…
Distributed medical images analysis on a Grid infrastructure
2007
In this paper medical applications on a Grid infrastructure, the MAGIC-5 Project, are presented and discussed. MAGIC-5 aims at developing Computer Aided Detection (CADe) software for the analysis of medical images on distributed databases by means of GRID Services. The use of automated systems for analyzing medical images improves radiologists’ performance; in addition, it could be of paramount importance in screening programs, due to the huge amount of data to check and the cost of related manpower. The need for acquiring and analyzing data stored in different locations requires the use of Grid Services for the management of distributed computing resources and data. Grid technologies allow…
CdTe Detectors
2014
Cadmium telluride (CdTe) compound semiconductors for x-ray detectors have experienced a rather rapid development in the last few years, due to their appealing performance. In this chapter we review the physical properties of semiconductor detectors for x-ray and γ ray spectroscopy. In particular, we focus on compound semiconductor detectors. We also review the principles of operation of both the semiconductor detectors and the electronic chains, with special emphasis on the digital techniques. CdTe detectors’ characteristics and performance enhancements are discussed in depth. Finally, we present some original results on CdTe detectors for medical applications.